Description
The structure of Veivot Technology's GY(F)TY53 optical fiber cable: 250um optical fibers are placed in loose tubes made of high modulus plastic. The loose tube is filled with waterproof filling compound. The center strength member is a steel wire or FRP (Fiber Reinforced Polymer), and for some optical cables with a number of cores, a layer of polyethylene (PE) needs to be extruded outside the steel wire or FRP. The loose tubes (and fillers) are stranded around the central strength component to form a compact circular core, and the gaps inside the cable core are filled with waterproof fillers. A layer of polyethylene inner sheath is extruded from the cable core, and double-sided plastic coated steel strip (PSP) is longitudinally coated and wrapped with polyethylene sheath to form the cable.
Features
Fiber counts: 2-288 fibers
Fiber Type: G652D; G657A1; G657A2; G657B3; G655C; OM1; OM2; OM3; OM4; OM5
Outer jacket: MDPE; HDPE
Excellent mechanical and temperature properties are guaranteed by precise excess fibers.
The key protection of fiber is based on excellent hydrolysis resistance.
It has excellent compression resistance and flexibility.
PSP enhancing misture-proof performance
It has good UV resistance, double PE sheath, and easy installation.
Application
Outdoor duct, buried directly and overhead
Standard
YD/T 901-2009
IEC 60794-1
Structure parameters of optical cable
Item | Contents | Unit | Parameters | ||||||||
Fiber | Count | / | 12 | 24 | 48 | 72 | 96 | 144 | 192 | 216 | 288 |
Central Strength Member | Material | / | Steel Wire | ||||||||
Loose Tube | Material | / | PBT | ||||||||
Water Blocking | Material | / | Water Blocking Tape | ||||||||
Inner Sheath | Material | / | PE | ||||||||
Color | / | Black | |||||||||
Thickness | / | 0.8mm | |||||||||
Armor | Material | / | Corrugated Steel Tape | ||||||||
Outer Sheath | Material | / | PE | ||||||||
Color | / | Black | |||||||||
Cable Diameter | ±0.5 | mm | 10.3 | 10.3 | 11.1 | 11.6 | 12.8 | 15.3 | 15.5 | 16.3 | 18.8 |
Cable Weight | ±10% | kg/km | 106 | 107 | 126 | 146 | 172 | 235 | 243 | 266 | 344 |
Mechanical & Environmental Performance
Item | Contents | Unit | Parameters |
Max. Tensile Strength | Short term | N | 3000 |
Long term | N | 1000 | |
Max. Crush | Short term | N/100mm | 1000 |
Long term | N/100mm | 300 | |
Min. Bending Radius | Operation | mm | 10 times of cable diameter |
Installation | mm | 20 times of cable diameter | |
Applicable Temperature Range | Operation | ℃ | -40 ~ +70 |
Installation | ℃ | -20 ~ +60 | |
Storage & Shipping | ℃ | -40 ~ +70 |